"EUCHNER CMS-RH safety switches are magnetic (non-contact) read heads using Hall Effect technology that sense a coded magnetic actuator. The read heads are vibration resistant and only respond to specifically coded actuator types to pervent tampering. CMS evaluation units can be chosen depending on the number of read heads used and the overall system safety category desired. The CMS magnetic systems are particularly suitable for areas where vibration, dirt and cleaning are major factors. Actuators and read heads can be fitted behind stainless steel making them ideal for pharmaceutical and food industry applications. Note: CMS actuators are sold separately. CMS requires the use of an external evaluation unit."

特性

  • Coded magnetic actuator and hall sensor
  • Can connect up to 30 sensors in series (Safety Category 2)
  • Can connect up to 4 sensors in parallel (Safety Category 4)
  • Variety of read head and actuator sizes and styles
  • LED self diagnostics
  • Wide sensing range
  • Achieves the highest level of safety
  • Non-contact system
  • Fault diagnostics
  • Sensors operate thru stainless steel
  • Long operational life
  • Operates under extreme environmental conditions e.g. dirt, moisture, ambient temperature
  • Overcomes misalignment issues
  • Vibration resistant
  • Minimizes down-time
  • Food machinery, etc
  • Switch-on distances of 6 and 10mm
  • Up to 5 meter cable standard
  • Surface or thru mounting
  • Environmental protection IP67- oil and dust tight, and water resistant
  • Ambient operating temperature -5 to 55C
  • Actuates from different directions
  • 20 year mission time with up to 166,000 cycles per year.

CMS-RH 非接触式安全互锁开关技术参数

点击查看 0 个替代产品
规格项 参数值 勾选搜索替代
性 能
动作范围 6 to 10 mm (0.2362 to 0.3937 inch)
环 境
工作温度 23 to 131 F (-5 to 55 C)
更多规格