特征:Built in alarm indicator; Programmable |
工作温度:-50 to 158 F (-45.56 to 70 C) |
产品类别:Dry Material (Powders) Level Switches |
Material Temperature Range:-58 to 356 F (-50 to 180 C) |
Maximum Operating Pressure:362 psi (255 m H2O) |
Measuring Range:? to 864 inch (? to 21946 mm) |
Meter Technology Type:Capacitive or RF Admittance |
Mounting Options:Side mount; Top mount |
Pole and Throw Specifications:Double Pole, Double Throw (DPDT) |
Switch Type:Electromechanical Switch |
特征:Built in alarm indicator; Programmable |
工作温度:-58 to 158 F (-50 to 70 C) |
产品类别:Dry Material (Powders) Level Switches |
Material Temperature Range:-58 to 752 F (-50 to 400 C) |
Max AC Voltage Rating:30 volts |
Max Current Rating:6 amps |
Max DC Voltage Rating:15000 volts |
Maximum Operating Pressure:145 psi (102 m H2O) |
Measuring Range:? to 780 inch (? to 19812 mm) |
Meter Technology Type:Capacitive or RF Admittance |
Mounting Options:Side mount; Top mount |
Pole and Throw Specifications:Double Pole, Double Throw (DPDT) |
Switch Type:Electromechanical Switch |
特征:Programmable |
工作温度:-60 to 160 F (-51.11 to 71.11 C) |
产品类别:Dry Material (Powders) Level Switches |
Communication Interface Options:Other Interface Type |
Material Temperature Range:-60 to 540 F (-51.11 to 282 C) |
Max AC Voltage Rating:253 volts |
Max Current Rating:6 amps |
Max DC Voltage Rating:253 volts |
Maximum Operating Pressure:360 psi (253 m H2O) |
Meter Technology Type:Vibrating or Tuning Fork Method |
Mounting Options:Side mount; Top mount |
Number of Switch Points Range:1 (#) |
Pole and Throw Specifications:Double Pole, Double Throw (DPDT) |
Switch Type:Electromechanical Switch |
特征:Programmable |
工作温度:-40 to 160 F (-40 to 71.11 C) |
重复性 :0.0400 +/-inch (1.02 +/-mm) |
产品类别:Dry Material (Powders) Level Switches |
Material Temperature Range:-40 to 300 F (-40 to 149 C) |
Max AC Voltage Rating:253 volts |
Max DC Voltage Rating:55 volts |
Maximum Operating Pressure:360 psi (253 m H2O) |
Meter Technology Type:Vibrating or Tuning Fork Method |
Mounting Options:Side mount; Top mount |
Number of Switch Points Range:1 (#) |
Pole and Throw Specifications:Double Pole, Double Throw (DPDT) |
Switch Type:Electromechanical Switch |
特征:Built in alarm indicator |
工作温度:-4 to 140 F (-20 to 60 C) |
产品类别:Dry Material (Powders) Level Switches |
Material Temperature Range:-4 to 170 F (-20 to 76.67 C) |
Maximum Operating Pressure:25 psi (17.59 m H2O) |
Meter Technology Type:Rotation Paddle |
Mounting Options:Side mount; Top mount |
Number of Switch Points Range:1 (#) |
Pole and Throw Specifications:Single Pole, Double Throw (SPDT) |
特征:Automatic Calibration |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:25 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:0.0500 mg/L |
Maximum wavelength of Light source:735 nm (7350 Å) |
Measured Parameter:Phosphorus |
Operating Temp:32 to 100 F (0.0 to 37.78 C) |
Output Options:Analog Current |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:0.0013 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:1.29E-5 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Aluminum |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:80 seconds |
显示类型:Digital |
工作温度:41 to 104 F (5 to 40 C) |
产品类别:Water Quality Testing Instruments |
Electrical Output:Analog Current; Switch / Alarm Relay |
Features and Functionality:Filters; Built-in or Self Calibration |
Form Factor:Wall ;Other |
Interface Options:Serial |
Process Temp:41 to 104 F (5 to 40 C) |
User Controls:Digital Front Panel |
Water Quality Parameters:Water Quality Measurement Instrument |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:10 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:0.0100 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Free Chlorine |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:60 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:5 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:0.1000 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Hexavalent Chromium |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:60 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:5 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:0.1000 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Copper |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:120 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:0.0065 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:6.46E-8 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Iron |
Operating Temp:40 to 100 F (4.44 to 37.78 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:180 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Display:Digital Readouts |
High Range:80 mg/L |
Instrument Type:Fixtured or Permanent |
Local Interface:Digital Front Panel |
Low Range:0.1000 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Hardness (Magnesium or Calcium) |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog Current |
Response Time:120 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:6.46E-4 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:1.29E-6 mg/L |
Maximum wavelength of Light source:565 nm (5650 Å) |
Measured Parameter:Hydrazine |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:60 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:0.0026 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:1.29E-6 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Manganese |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:300 seconds |
特征:Automatic Calibration |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:3 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:1.00E-5 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Nitrite |
Operating Temp:32 to 100 F (0.0 to 37.78 C) |
Output Options:Analog Current |
Response Time:7200 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:50 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:0.0500 mg/L |
Maximum wavelength of Light source:880 nm (8800 Å) |
Measured Parameter:Phosphate |
Operating Temp:104 to 212 F (40 to 100 C) |
Output Options:Analog Current |
Response Time:360 seconds |
特征:Automatic Calibration; Data Storage or Data Logging |
产品类别:Water Quality Photometers and Colorimeters |
Computer Interface:Computer Interface |
Display:Digital Readouts |
High Range:0.0065 mg/L |
Instrument Type:Fixtured or Permanent |
Interface Options:Serial Interface |
Local Interface:Digital Front Panel |
Low Range:1.29E-6 mg/L |
Maximum wavelength of Light source:810 nm (8100 Å) |
Measured Parameter:Silica |
Operating Temp:41 to 104 F (5 to 40 C) |
Output Options:Analog current signal; Switch or alarm signal |
Response Time:90 seconds |
精度:0.1000 % |
工作温度:14 to 104 F (-10 to 40 C) |
产品类别:Total Organic Carbon (TOC) Analyzers |
Analytes Measured:Total Organic Carbon; COD, BOD, SAC |
Detector Type:Xeon Light |
Average Analysis Time:2 minutes |
Local Interface:Digital Front Panel |
Display Options:Video Display |
General Features:Measures Solids; Built-in or Self Calibration (optional feature) |
Analysis Method:UV Fluorescence |
Sample Introduction:Insertion ;Other |
Measurement Range:10 to 2000 ppm |
Process Temperature Range:14 to 104 F (-10 to 40 C) |
Additional Outputs:Analog Current; Switch or Relay |
工作温度:-4 to 140 F (-20 to 60 C) |
特征:Built-in Alarm Indicator; Recorder / Totalizer Functions |
产品类别:Mass Flow Meters and Controllers |
Additional Variables Measured:Temperature |
Process Media Type:Gas |
Meter Type:Mass Flow Meter |
Electrical Output:Analog Current; Frequency; Switch |
Approvals:CE, C-tick, Ex Approvals |
Media Temperature:-40 to 266 F (-40 to 130 C) |
Interface Options:Network / Fieldbus |
Front Panel Interface:Digital Front Panel |
End Fittings:In-line Flanged |
Operating Pressure:580 psi (408 m H2O) |
Display:Digital |
Meter Technology:Thermal |
Mounting:In-line |
Pipe Diameter:0.50 to 4.00 inch (12.7 to 102 mm) |
Mass Flow Rate:0.0183 to 138 lbs/min (4.99E-4 to 3.74 metric tons/hr) |
工作温度:-40 to 140 F (-40 to 60 C) |
特征:Built-in Alarm Indicator; Recorder / Totalizer Functions |
产品类别:Mass Flow Meters and Controllers |
Meter Technology:Thermal |
Pipe Diameter:0.50 to 2.00 inch (12.7 to 50.8 mm) |
Process Media Type:Liquid; Gas |
Display:Digital |
Operating Pressure:-7.25 to 580 psi (-5.1 to 408 m H2O) |
Electrical Output:Analog Current; Frequency; Switch |
End Fittings:In-line Flanged |
Media Temperature:-40 to 212 F (-40 to 100 C) |
Meter Type:Mass Flow Meter |
Mass Flow Rate:0.0183 to 50.05 lbs/min (4.99E-4 to 1.36 metric tons/hr) |
Approvals:CE, C-tick, Ex Approvals |
Mounting:In-line |
Interface Options:Network / Fieldbus |
Front Panel Interface:Digital Front Panel |
Additional Variables Measured:Temperature |
工作温度:-40 to 140 F (-40 to 60 C) |
特征:Built-in Alarm Indicator; Recorder / Totalizer Functions |
产品类别:Mass Flow Meters and Controllers |
Additional Variables Measured:Temperature |
Approvals:CE, C-tick, Ex Approvals |
End Fittings:In-line Flanged |
Meter Type:Mass Flow Meter |
Display:Digital |
Mounting:In-line |
Process Media Type:Liquid; Gas |
Mass Flow Rate:0.0 to 26460 lbs/min (0.0 to 720 metric tons/hr) |
Front Panel Interface:Digital Front Panel |
Electrical Output:Analog Current; Frequency; Switch |
Interface Options:Network / Fieldbus |
Meter Technology:Thermal |
Pipe Diameter:3.00 to 60.00 inch (76.2 to 1524 mm) |
Operating Pressure:-7.25 to 290 psi (-5.1 to 204 m H2O) |
Media Temperature:-40 to 212 F (-40 to 100 C) |
工作温度:41 to 95 F (5 to 35 C) |
产品类别:Total Organic Carbon (TOC) Analyzers |
Local Interface:Digital Front Panel |
Display Options:Digital Readout |
General Features:Built-in or Self Calibration |
Process Temperature Range:32 to 104 F (0.0 to 40 C) |
Detector Type:Thermic Catalytic Combustion |
Sample Introduction:On-Line |
Measurement Range:0.2500 to 12000 ppm |
Additional Outputs:Analog Current |
Analysis Method:Combustion |
Analytes Measured:Total Organic Carbon |
查看更多